TM 5-3895-370-14&P5-34.ALTERNATOR ASSEMBLY REPAIR (CONT).(2)Measure resistance of excitation winding in rotorat points C and D. Resistance value is 7.0 Ohmto 7.1 Ohm.(3)Test stator for short circuit at points E and F with80 Vac. Indicator lamp must not light up.(4)Measure resistance of stator windings betweenphase lead-out wires (point E).Resistance value is 0.14 Ohm to 0.24 Ohm.d.Assembly.(1)Install bearing retainer (39) in housing (2).5-90