TM 5-3895-370-14&P
5-35.
STARTER TESTING (CONT).
(3)
Perform following no-load test prior to disassembly:
(a)
Connect voltmeter from starter motor terminal to starter motor frame. Connect negative battery cable to
starter motor frame.
(b)
Mount tachometer to measure armature speed.
WARNING
Ensure switch is open prior to connecting to starter solenoid. Electrical shock or
physical injury may result if starter is energized while making final battery
connection.
(c)
Connect switch to solenoid battery terminal and solenoid switch terminal.
(d)
Connect ammeter in series between positive side of battery and battery terminal on starter solenoid.
(e)
Connect potentiometer between positive and negative battery terminals.
(f)
Close switch to operate starter and adjust potentiometer until voltmeter indicates 24 Vdc.
(g)
Record ammeter and tachometer readings.
(h)
Open switch to de-energize starter.
(i)
Refer to Table 5-3 for current and rpm performance specifications.
5-94