TM 5-3895-370-14&P
Table 5-3. Starter No-Load Test Specifications
No - Load Test ( Includes Solenoid Current)
Volts
Min Amps
Max Amps
Min RPM
Max RPM
24
105
115
9000
13400
(j)
Remove test equipment from starter assembly. If measured performance is not within specifications, go to
step four. If measured performance is within specifications, starter is functioning correctly.
(4)
If pinion rotates and measured performance is not within specifications, perform following no-load test.
(a)
Remove solenoid (para 5-36).
(b)
Connect voltmeter from starter motor terminal to starter motor frame.
(c)
Connect negative battery terminal to starter motor frame.
(d)
Mount tachometer to measure armature rpm.
5-95