(5)
Remove three elbows (12, 13, and 14) and two
adapters (15 and 16) from motor (10).
(6)
Remove and discard two preformed packings
(17 and 18) from two adapters (15 and 16).
(7)
Remove and discard preformed packing (19)
from elbow (13).
b. Disassembly.
CAUTION
·
When clamping motor in vise do not clamp motor across motor housing, clamp
across mounting flange. Failure to comply may cause damage to equipment.
·
Do not mark or scratch mounting flange. Use soft jawed vise when clamping
motor. Failure to comply may cause damage to equipment.
·
Mounting flange may become distorted if excessive clamping pressure is used.
Do not use excessive clamping pressure. Failure to comply may cause
damage to equipment
(1)
Place motor (1) in vise with valve b ody (2)
upward.
(2)
Remove four screws (3 and 4).
CAUTION
Loose parts may fall if valve body is
not removed carefully. Lift valve
body straight upward when removing.
Failure
to
comply
may
cause
equipment damage.
(3)
Remove valve body (2).
5-163