TM 5-3895-370-14&P5-48. HYDRAULIC MOTOR REPLACEMENT/REPAIR (CONT).NOTE·Arbor press may be required toremove shaft and bearingassembly from bearing housing.·Do not disassemble shaft andbearing assembly. They arereplaced as an assembly.(20)Remove shaft and bearing assembly (32) frombearing housing (23).(21)Remove and discard key (33).(22)Remove shaft face seal (34) from bearinghousing (23). Discard shaft face seal.c. Cleaning/Inspection.WARNING·Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protectivegoggles and gloves; use only in a well-ventilated area; avoid contact with skin,eyes, and clothes and do not breathe vapors. Keep away from heat or flame.Never smoke when using solvent; the flash point for type I drycleaning solventis 100°F (38°C) and for type II is 140°F (60°C). Failure to do so may result ininjury or death to personnel. P-D-680 type III is a substitute for types I and II inthis application. The flash point for type III is 200°F (93°C).·If personnel become dizzy while using cleaning solvent, immediately get freshair and medical help. If solvent contacts skin or clothes, flush with cold water.If solvent contacts eyes, immediately flush eyes with water and get immediatemedical attention.(1)Clean all metal parts with drycleaning solvent.WARNINGCompressed air is used for cleaning purposes and will not exceed 30 psi (207 kPa).Use only with effective chip guarding and personal protective equipment (goggles,gloves, etc.).(2)Dry all parts with compressed air.(3)Check parts for damage.(4)Replace damaged parts.5-166