TM 5-3895-370-14&P5-54.BITUMINOUS PUMP BASE REPLACEMENT.This task covers:a. Removalb. InstallationINITIAL SETUPToolsPersonnel RequiredShop equipment, automotive maintenance andMOS 62B, Construction equipment repairer (2)repair: field maintenance, supplemental no. 1,less powerEquipment ConditionTM or ParaCondition DescriptionMaterials/PartsPara 4-150Pump sensor bracketLockwashers (4)removed.Para 5-53Bituminous pumpremoved.a.RemovalWARNINGPump base weighs 45 lbs (20 kg). Attach suitable lifting device prior toremoval/installation. Failure to do so may result in injury or death to personnel.(1)Attach a suitable lifting device to pump base (1).5-201