TM 5-3895-370-14&P
5-53.
BITUMINOUS PUMP REPLACEMENT/REPAIR (CONT).
e.
Installation.
WARNING
Bituminous pump weighs 583 lbs (264 kg). Attach suitable lifting device prior to
installation. Failure to do so may result in injury to personnel.
(1)
Attach a suitable lifting device to pump (5).
(2)
With aid of two assistants, install shims (7) and pump (5) on pump base (6).
(3)
Install four screws (4), washers (3), lockwashers (2) and nuts (1).
NOTE
Follow-on maintenance:
Install hydraulic motor (para 5-48).
Adjust bituminous pump and hydraulic motor alinement.
Install bituminous pipes (para 5-55).
Install pump heating chamber (para 5-58).
END OF TASK
5-200