TM 5-3895-370-14&P5-53.BITUMINOUS PUMP REPLACEMENT/REPAIR (CONT).e.Installation.WARNINGBituminous pump weighs 583 lbs (264 kg). Attach suitable lifting device prior toinstallation. Failure to do so may result in injury to personnel.(1)Attach a suitable lifting device to pump (5).(2)With aid of two assistants, install shims (7) and pump (5) on pump base (6).(3)Install four screws (4), washers (3), lockwashers (2) and nuts (1).NOTEFollow-on maintenance:Install hydraulic motor (para 5-48).Adjust bituminous pump and hydraulic motor alinement.Install bituminous pipes (para 5-55).Install pump heating chamber (para 5-58).END OF TASK5-200