TM 5-3895-370-14&P
(5)
Assemble spray valve assembly as follows:
NOTE
·
Spray nozzles on spraybar and
spraybar extensions are installed
in the same way.
·
The spray nozzles on spraybar
have a smaller spray orifice than
nozzles on spraybar extensions.
Refer to the RPSTL for proper
nozzle application.
(a)
Install spray nozzle (63) in valve body
(61).
NOTE
Apply a coat of oil on preformed
packing prior to installing.
(b)
Install preformed packing (62) on nozzle
spool (59).
(c)
Install nozzle spool (59) in valve body (61)
as an assembly.
(d)
Install retaining ring (60) on nozzle spool
(59).
(e)
Install pin lever (58) and cotter pin (57) on
nozzle spool (59).
NOTE
Spray valve assemblies on spraybar
and spraybar extensions are installed
in the same way.
(6)
Install gasket (56) and spray valve assembly
(55) on center support section (15) with two fiber
washers (54) and screw (53).
(7)
Repeat Step (6) above to install remaining 13
spray valve assemblies (55).