Generator Bearing (Inside Bearing Type RFA)
Disassembly and Assembly
Generator Bearing (Inside Bearing Type RFA)
9. Put the bottom shield (7) in place and install six bolts.
10. Remove cardboard from between the stator and
rotor assemblies.
11. Put the core assembly (exciter field) (8) in position
on the bracket.
12. Install two long bolts. Install two bolts and nuts.
13. Connect two wires (F1 and F2) (9) to the regulator
terminal strip.
14. Tie the wires together with plastic ties.
NOTICE
Do not cause damage to the exciter
field when installing the exciter and
heat sink assembly.
15. Position the exciter and heat sink assembly (10) on
the rotor shaft and install two bolts.
136