TM 10-4320-303-133.4.1 6InchHoseAssemblyRepair.(Continued)Figure 3-10. Spacing of Buckles on Repaired 6-Inch Hose Assembly.CAUTIONTo avoid leaks at adaptor shoulder, buckles must use alternately positioned asshown in figure 3-10.v. Repeating steps i through u, install second, third and fourth strapping and buckle in an offset as shown infigure (3-10).w. Repeat step h and install male quick-disconnect coupling half (1) on second hose end.Figure 3-11. Repaired Hose Connection.x. Refer to paragraph 2.3.3.1 and connect hose ends (Figure 3-11, 1) with grooved-end pipe quick disconnectcoupling clamp (2).y. Release hose clamps (Figure 3-1, 1) and inspect repaired section for leaks.3-11