TM 10-4320-346-12&PTable 3-1. Operator Troubleshooting. - Continued.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION5. HOSE ASSEMBLY LEAKS.- Continued.Step 4. Hose assembly is defective.Notify unit maintenance.6. LEAKS OCCUR AT JOINTS OF COMPONENTS.Step 1. Cam-lock couplings are improperly fastened.Disconnect couplings from component and then reconnect couplings. Be sure that the coupling cam-locking mechanism is properly positioned to seal the component joint.Step 2. Dust or dirt is trapped inside the component coupling connection.Disconnect couplings from component and check for dust or dirt inside couplings. Remove any dust ordirt found and reconnect component.Step 3. Gaskets are missing from connection joints.Take affected joint connection apart and check that gasket is properly placed within the coupling half. Ifgasket is missing, contact unit maintenance for a replacement gasket.Step 4. Component parts are defective.Notify unit maintenance.7. COMPONENTS LEAK AT PLACES OTHER THAN JOINTS.Component parts are defective.Notify unit maintenance.3-4
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business