TM 5-3895-370-14&P
5-60. SIDE JOINT SECTION REPAIR (CONT).
NOTE
Only the left side joint section has
the universal coupling.
(16)
Disassemble spring assembly as follows:
(a)
Remove universal coupling (44), stud (45),
and two end plugs (46) from spring (47).
(b)
Remove lube fitting (48) from universal
coupling (44).
b. Cleaning/Inspection.
WARNING
·
Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective
goggles and gloves; use only in a well-ventilated area; avoid contact with skin,
eyes, and clothes and do not breathe vapors. Keep away from heat or flame.
Never smoke when using solvent; the flash point for type I drycleaning solvent
is 100°F (38°C) and for type II is 140°F (60°C). Failure to do so may result in
injury or death to personnel. P-D-680 type III is a substitute for types I and II in
this application. The flash point for type III is 200°F (93°C).
·
If personnel become dizzy while using cleaning solvent, immediately get fresh
air and medical help. If solvent contacts skin or clothes, flush with cold water.
If solvent contacts eyes, immediately flush eyes with water and get immediate
medical attention.
(1)
Clean all metal parts with drycleaning solvent.
WARNING
Compressed air is used for cleaning purposes and will not exceed 30 psi (207 kPa).
Use only with effective chip guarding and personal protective equipment (goggles,
gloves, etc.).
(2)
Dry all parts with compressed air.
(3)
Check parts for damage.
(4)
Replace damaged parts.
c. Assembly.
NOTE
Only the left side joint section has the universal coupling.
(1)
Assemble spring assembly as follows:
(a)
Install lube fitting (48) on universal coupling (44).
(b)
Install two end plugs (46), stud (45), and universal coupling (44) on spring (47).
5-240