TM 10-3835-223-13&PTable 3-1. Operator Troubleshooting - cont.MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION8. REEL TURNS COUNTERCLOCKWISE WHEN CW IS SELECTED.Step 1. Check position of REEL CW/CCW switch.Set switch to CCW or CW, as required.Step 2. Check for reversed hose connections at quick disconnect couplings.Refer to MALFUNCTION 2, Step 2.NOTEIf malfunction cannot be corrected, notify unit maintenance.9. REEL TURNS VERY SLOWLY.Step 1. Verify that brake is released.Raise brake lever to up position.Step 2. Check for tangled hose. Hose may be dragging on frame unit.Untangle hose from frame.Step 3. Check fluid level in hydraulic reservoir.If fluid in reservoir is low, notify unit maintenance.Step 4. Check for 24Vdc electrical power from slave vehicle.Connect slave cable to vehicle with adequate electrical output.NOTEIf malfunction cannot be corrected, notify unit maintenance.3-5