TM 10-4320-303-13
Components
Table 2-11. Components Required from Storage Assembly Crate for Assembly of Storage Assembly.
Qty
Size
Item
16
0.375 16 UNC-2A
Bolt
X 3.25 inches
1
4 inch
Coupling half, female, quick disconnect
1
4 inch
Coupling half, male, quick-disconnect
1
4 inch
Coupling pipe fitting
NOTE
Required number of discharge hose assemblies depends on distance between
hoseline segment and storage assembly. Any unused hose assemblies can be
used as spares.
4
4 inch x 10 foot
Discharge hose assembly, quick disconnect
1
4 inch
Male flanged coupling half
32
0.046 ID x 0.812
Flat washer
OD
2
4 inch, Class 150
Gasket
1
4 inch
Gate valve, flanged
1
4 inch
Grooved-end pipe quick disconnect coupling
clamp
16
0.375 16 UNC-2B
Hex nut
1
6 inch x 6 inch
Reducing tee
2.3.6.2 Assembly and Installation Procedures.
CAUTION
To prevent damage to storage assembly, DO NOT choose site subject to flooding or high water.
To prevent damage to storage tank, DO NOT walk on tank unless you must. DO NOT drop sharp
objects on tank.
After removing components from boxes, be sure to protect them from sand and grit.
a. Place gasket (Figure 2-21, 14) on male flanged coupling half (18). Place 4 inch gate valve (12) on male
flanged coupling half (18). Align holes of 4 inch gate valve (12), gasket (14), and male flanged coupling
half (18).
b. Place eight flat washers (17) on eight bolts (19). Insert bolts through openings on male flanged coupling half
(18), gasket (14), and 4 inch gate valve (12).
2-48