TM 10-4320-303-132.3.7 Assembly of Distribution Points. (Continued)Table 2-12. Components Required from Distribution Point Crate for Assembly of Distribution Points.(Continued)QtySizeItem14 inchCoupling half, quick disconnect, male external pipe thread72 inch x 20 feetHose assembly32 inch x 2 inch x 2 inchY-connector, quick disconnect21.5 inch x 2 inchReducer, external pipe thread, quick disconnect, female22 inchHose swivel2Nozzle22 inchDust plug22 inch x 2 inchElbow valve236 gallonDrinking water storage bag2Nozzle stand assembly2.3.7.2 Assembly and Installation.a. Locate male filler/discharge elbow (Figure 2-23, 1) on storage tank.CAUTION'After removing components from boxes, be sure to protect them from sand andgrit.b. Push cam arms on female end of reducer (2) forward to open position.CAUTIONTo prevent leakage, close both cam arms at the same time.Do not strike cam arms to close. Damage to couplings may result.c. Connect female end of reducer (2) to male filler/discharge elbow (1). Close cam arms.d. Push cam arms on rigid-walled suction hose (3) forward to open position.CAUTIONTo prevent leakage, close both cam arms at the same time.Do not strike cam arms to close. Damage to couplings may result.e. Connect rigid-walled 2 inch X 20 foot suction hose (3) to reducer (2) attached to male filler/dischargeelbow (1). Close cam arms.f. Locate suction port (4) and discharge port (5) on 125 GPM pumping assembly (6). Referenceapplicable technical manual for preparation for use of the 125 GPM pumping assembly (6).2-52