TM 10-4320-303-13
CAUTION
To prevent leakage, close both cam arms at the same time.
Do not strike cam arms to close. Damage to couplings may result.
p. Connect male by female reducer (18) to female quick-disconnect coupling half (17). Close cam
arms.
q. Push cam arms on male by female reducer (18) forward to open position.
CAUTION
To prevent leakage, close both cam arms at the same time.
Do not strike cam arms to close. Damage to couplings may result.
r. Connect discharge hose (9) to male by female reducer (18). Close cam arms.
NOTE
Wrap antiseize tape in direction of threads.
s. Wrap antiseize tape (item 9, appendix E) around threads on male quick- disconnect coupling half
(19). Screw male quick-disconnect coupling half (19) into outlet port (11) on hypochlorination unit
1955-3 (12).
t. Push cam arms on reducer (20) forward to open position.
CAUTION
To prevent leakage, close both cam arms at the same time.
Do not strike cam arms to close. Damage to couplings may result.
u. Connect reducer (20) to male quick-disconnect coupling half (19) attached to hypochlorination unit
1955-3 (12). Close cam arms.
v. Push cam arms on discharge hose (21) forward to open position.
CAUTION
To prevent leakage, close both cam arms at the same time.
Do not strike cam arms to close. Damage to couplings may result.
w. Connect discharge hose (21) to reducer (20). Close cam arms.
NOTE
Steps x through ad are for the installation of hypochlorination units 1955-1 and A-
506131. Refer to applicable technical manual for preparation for use of
hypochlorination unit A-506131.
x. Unscrew two dust caps (22) from inlet port (10) and outlet port (11) of unit 1955-1 (13). Store dust
caps (22) for later use.
2-55