TM 10-4320-303-13NOTEIf tank trucks are to be filled, install reducers, to match truck fitting, on dischargehoses (9 or 15).When reducers are installed on hose ends, water flow is controlled by 2 inch gatevalves (5 or 11).Wrap antiseize tape in direction of threads.ar. Wrap antiseize tape (item 9, appendix E) around threads on two reducers (16). Screw reducers (16)into two hose swivels (17).NOTEWrap antiseize tape in direction of threads.as. Wrap antiseize tape (item 9, appendix E) around threads of two hose swivels (17). Screw two hoseswivels (17) into two nozzles (18).at. Push cam arms on two reducers (16) forward to open position.CAUTIONTo prevent leakage, close both cam arms at the same time.Do not strike cam arms to close. Damage to couplings may result.au. Connect two reducers (16) to two discharge hoses (15). Close cam arms.av. Push cam arms on ends of two elbow valves (19) forward to open position.CAUTIONTo prevent leakage, close both cam arms at the same time.Do not strike cam arms to close. Damage to couplings may result.aw. Connect two elbow valves (19) to two discharge hoses (9). Close cam arms.ax. Push cam arms on open ends of two elbow valves (19) forward to open position.CAUTIONTo prevent leakage, close both cam arms at the same time.Do not strike cam arms to close. Damage to couplings may result.ay. Connect two dust plugs (20) to two elbow valves (19). Close cam arms.2-59