TM 10-4320-303-13
NOTE
If tank trucks are to be filled, install reducers, to match truck fitting, on discharge
hoses (9 or 15).
When reducers are installed on hose ends, water flow is controlled by 2 inch gate
valves (5 or 11).
Wrap antiseize tape in direction of threads.
ar. Wrap antiseize tape (item 9, appendix E) around threads on two reducers (16). Screw reducers (16)
into two hose swivels (17).
NOTE
Wrap antiseize tape in direction of threads.
as. Wrap antiseize tape (item 9, appendix E) around threads of two hose swivels (17). Screw two hose
swivels (17) into two nozzles (18).
at. Push cam arms on two reducers (16) forward to open position.
CAUTION
To prevent leakage, close both cam arms at the same time.
Do not strike cam arms to close. Damage to couplings may result.
au. Connect two reducers (16) to two discharge hoses (15). Close cam arms.
av. Push cam arms on ends of two elbow valves (19) forward to open position.
CAUTION
To prevent leakage, close both cam arms at the same time.
Do not strike cam arms to close. Damage to couplings may result.
aw. Connect two elbow valves (19) to two discharge hoses (9). Close cam arms.
ax. Push cam arms on open ends of two elbow valves (19) forward to open position.
CAUTION
To prevent leakage, close both cam arms at the same time.
Do not strike cam arms to close. Damage to couplings may result.
ay. Connect two dust plugs (20) to two elbow valves (19). Close cam arms.
2-59