SERVICE MANUALTROUBLE SHOOTING THE CR BRAKEMASTER UNIT (Cont’d)SYMPTOMPROBABLE CAUSEREMEDYDoes not cool air (initial1. Mounted in location where itRelocate unit.installation).cannot be cooled by ambientair.2. Mounted too near heat produc-Relocate unit.ing equipment or too nearother heat dissipating equip-ment.3. Copper tubing from compressorIncrease length of copperto inlet too short.tubing.Does not "unload" when com-1. UNL port of governor not con-Connect or repair line.pressor goes into stand-bynected to unloader port ormode.line broken.2. Components of unloader valveRebuild unloader valve.worn.3. Ice formed in area of un-Shorten line (24" min. allowableloader valve.length) and/or install heater.4. Heater inoperative.Replace heater or check electri-cal connections.Safety valve opens.1. Check valve in outlet stuckClean outlet and replace checkclosed.valve assembly.2. Obstruction in air line beyondRemove obstruction.heat exchanger.3. Compressor governor valveReplace.defective.4. Safety valve defective.Replace.Water exhausted by unit con-1. Compressor rings defective.Rebuild or replace compressor.tains excessive oil and/or soot.No water exhausted during un-1. Insufficient water in ambientloading cycle.(inlet) air.2. Not cooling air sufficiently toLengthen copper line from com-condense water.pressor to heat exchanger (36"max. length allowable). Relocateheat exchanger to area of greaterambient air flow.Compressed air was cooled by1. Covered with dirt or paint.Steam clean and/or remove paint.unit but no longer is cooled2. Deflector damaged or broken.Replace deflector assembly.properly.Water exhausted is brownish1. Broken or damaged deflector.Replace deflector assembly.or brown particles are ex-hausted.CTS-4079 - CHAPTER XIV - Page 22
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business