SERVICE MANUAL
Fig. 28
1
End Yoke
7
Snap Ring
2
U-Bolt
8
Sleeve Yoke
3
Nut
9
Cork Washer
4
Lock Washer
10 Steel Washer
5
Bearing Assembly
11 Dust Cap
6
Journal Assembly
CLEANING AND INSPECTION
1.
Clean All Parts - Use a suitable cleaning fluid. Allow
the parts to remain in the cleaner for some time to
loosen up any particles of grease or foreign matter.
Re-move any burrs or rough spots from any
machined surfaces.
2.
Needle Bearings - Do not disassemble. Clean with
short stiff brush and blow out with compressed air.
Work a small quantity of lubricant into each bearing
cap and turn the needle bearing on the trunnion to
check wear. Replace if worn.
3.
Journal Cross - Because worn needle bearings used
with a new journal cross or new needle bearings
used with a worn journal cross will wear more rapidly
making another replacement necessary in a short
time, always replace the journal cross and four
needle bearing caps as a unit.
4.
Journal and Bearing Kit (Figs. 29 and 30) - To
facilitate the replacement of journals and bearings, a
Journal and Bearing Kit is available. The use of the
Kit insures having the correct individual parts when
required and saves valuable time.
Fig. 30
CTS-4017 - Page 16
PRINTED IN UNITED STATES OF AMERICA