SERVICE MANUAL
CALIBRATION
Section 5
Before mounting pump on stand remove access plug
with screwdriver bit KDEP 2949. Remove fuel inlet
adapter and plug opening with bushing 1 413 462 040
and copper gasket 2 916 710 611 so it is flush with pump
housing.
ESTABLISH PORT CLOSURE ON NO. 1 CYLINDER
1. Mount pump on stand and install rack dial indicator 1
687 233 015, bracket 1 688 130 030, adapter bushing 1
683 350 065 and rack pin 1 683 201 013 (Figure 2).
Figure 2. Installing Dial Indicator (Rack Gauge)
1.
Bracket 1 688 130 030 with Adapter
Bushing 1 683 350 065 and Rack Pin 1 683
201 013.
2.
Dial Indicator 1 687 233 015
2.
Zero dial indicator when rack is pushed to shut-
off. Be sure rack does not bottom out on
indicator. Move throttle lever to max. position
Total rack travel should be as specified on
individual pump calibration chart for starting fuel
delivery (Step 17).
3.
Move rack out of starting fuel position with shut-
off lever. Dial indicator should read about 10
mm 2 mm.
4.
Mount lift-to-port closure measuring device 1 688
130 135 with dial indicator 1 687 233 012,
adapter bushing 1 683 350 066 and tappet pin 1
682 012 008 to pump (Figure 3). Make sure
tappet number one is at bottom dead center
(B.D.C.). The plunger lift-to-port
closure is the distance in mm from the B.D.C. position of
the cam to port closing by the plunger. Lift-to-port
closure is only measured at element number one.
Subsequent elements are phased at 60 degree intervals
(see Step 10).
5.
Zero the dial indicator at bottom dead center
position of the roller tappet.
IMPORTANT
HIGH
PRESSURE
PHASING
IS
RECOMMENDED. (FOR LOW PRESSURE
PHASING
REMOVE
DELIVERY
VALVE,
SPRING
AND
WASHER.
UPON
REPLACEMENT, NEW DISCHARGE FITTING
AND GASKET AT BOTTOM OF DELIVERY
VALVE ARE REQUIRED EACH TIME AS
THEY ARE A ONE-TIME TORQUE DESIGN).
Figure 3. Establishing Initial Plunger Lift (No. 1 Pumping
Element)
1.
Dial Indicator 1 687 233 012
2.
Plunger Lift Device 1 688 130 135 with Pin
1 682 012 008 and Adapter Bushing 1 683
350 066.
6.
With the bleeder screw open at number one
calibrating nozzle holder assembly, increase
feed pressure until calibration fluid comes out of
overflow tube with no bubbles.
7.
Turn camshaft slowly in direction of rotation
(clockwise) until port closure is reached. Port
closure is reached when the flow of calibrating
fluid from nozzle holder overflow tube changes
from a steady stream to drops.