TM 5-4320-301-13&P
TM 08936A-13&P/1
Section V
ORGANIZATIONAL MAINTENANCE PROCEDURES (Contd.)
4-12. STAND ASSY, REPAIR. (Contd.)
CLEANING AND INSPECTION
Dry-cleaning solvent, P-D-680, used to clean parts is potentially
dangerous to personnel and property. Avoid inhalation of fumes and
repeated or prolonged skin exposure. Wash exposed skin thoroughly
with soap and water. Use in well ventilated area away from open
flame or excessive heat. Flash point is 100oF (38°C).
a. Wash all parts in cleaning solvent P-D-680 to remove all dirt and
foreign matter. Dry with clean lint free
cloth.
b. Inspect nozzle stand assy in accordance with PMCS.
c. Using proper tools, straighten any bent legs or brackets. Weld any
minor cracks or breaks that were detected during inspection. Replace
any leg or bracket that is damaged beyond repair.
d. If either chain is damaged, cut a new one approximately 10-inches in
length from bulk chain (P/N RRC-271).
e. Replace any remaining parts that are damaged or defective.
4-16