TM 5-3895-370-14&P
b. Disassembly.
NOTE
This task shows disassembly of one
rocker arm. The procedure is the
same for all rocker arms.
(1)
Remove two retaining rings (1), washers (2),
and rocker arms (3) from arm support (4).
(2)
Remove two nuts (5) and pushrod adjusting
screws (6).
(3)
If damaged, remove expansion plug (7) from
arm support (4).
c. Cleaning/Inspection.
WARNING
Compressed air used for cleaning
purposes will not exceed 30 psi (207
kPa). Use only with effective chip
guarding and personal protective
equipment (goggles/shield, gloves,
etc).
(1)
Clean all parts of rocker arm assembly in strong
detergent and hot water. Rinse in clean hot
water and use compressed air to dry all parts.
(2)
Check rocker arm for cracks, excessive wear,
and other damage. Replace all rocker arms
failing inspection.
(3)
Measure rocker arm bore as indicated. Normal
measurement is 0.7480 to 0.7500 in. (18.9992-
19.05 mm). If above or below normal
measurement, replace rocker arm.
5-51